Cleanroom Ceiling Panels Manufacturer

Glostar manufactures cleanroom ceiling panels and modular cleanroom ceiling systems for pharmaceutical, biotechnology, electronics, semiconductor, food processing, laboratory, medical and other controlled environments. Our cleanroom ceiling panels are available with rock wool, magnesium oxide composite, aluminum honeycomb, PU/PIR and other project-specific constructions. 

Нам доверяют более 1000 клиентов

CE, ISO

Choose the Right Cleanroom Ceiling Panels for Your Project

Glostar provides cleanroom ceiling panels and modular ceiling systems for pharmaceutical, biotechnology, semiconductor, electronics, food processing and laboratory facilities. Available with rock wool, MGO composite, aluminum honeycomb and PU/PIR cores, our ceiling panels can be customized to match your cleanroom layout, support system and project specifications.
We support contractors, EPC companies and project owners with customized panel dimensions, coordinated openings for HEPA filters, FFUs and lighting, technical drawings and project-based manufacturing.

Потолочные панели для чистых помещений
Cleanroom ceiling panels coordinated with lighting, air filtration and service openings for an integrated ceiling system.

What Are Cleanroom Ceiling Panels?

Cleanroom ceiling panels are prefabricated enclosure components used to form the overhead boundary of controlled environments such as pharmaceutical cleanrooms, biotechnology facilities, semiconductor plants, electronics manufacturing areas, food processing rooms and laboratories.

Unlike conventional suspended ceilings, a cleanroom ceiling works as part of an integrated enclosure system. Ceiling panels, supporting structures, joints and service openings need to coordinate with cleanroom walls, HEPA filters, fan filter units (FFUs), lighting, sprinklers, access hatches and other building services.

A typical cleanroom ceiling panel consists of metal facings combined with an insulated or structural core. Depending on project requirements, core materials may include rock wool, MGO composite, aluminum honeycomb, PU/PIR and other engineered configurations.

The appropriate ceiling panel should be selected according to fire requirements, ceiling span, support spacing, panel weight, thermal performance, maintenance requirements, cleaning procedures and equipment openings.

Cleanable Ceiling Surfaces

Smooth metal surfaces and carefully designed joints help create a cleanable overhead enclosure. Surface materials and coatings should be selected according to the facility’s cleaning agents, disinfectants, humidity and operating conditions.

Coordinated Openings

HEPA filters, FFUs, lights, sprinklers and access hatches should be coordinated with the ceiling layout before panel fabrication. Prefabricated openings can reduce unnecessary site cutting and improve installation efficiency.

Maintenance Ceiling Access

Not every cleanroom ceiling panel is designed to support personnel. Where maintenance access is required, the complete ceiling assembly — including panels, reinforcement, supports and connections — should be designed and verified for the specified loads.

Three Types of Cleanroom Ceiling Panels by Glostar

Cleanroom ceiling panels are available in different constructions to meet the requirements of cleanroom layout, installation method, ceiling support system and service integration. The appropriate panel type depends on the project scale, module dimensions, required openings, maintenance access and technical specifications. Glostar provides prefabricated, machine-made and customized cleanroom ceiling panels for pharmaceutical, electronics, semiconductor, food processing, laboratory and other controlled-environment projects.
Prefabricated Cleanroom Ceiling Panels

Prefabricated Cleanroom Ceiling Panels

Prefabricated cleanroom ceiling panels are manufactured according to approved project dimensions and ceiling layouts. Panel size, core material, facing, edge details, reinforcement and service openings can be coordinated before production.

For projects involving HEPA filters, FFUs, lighting, sprinklers or access hatches, prefabrication can help reduce unnecessary cutting and modification during site installation.

These panels are particularly suitable for cleanroom projects with customized ceiling layouts, multiple service openings or specific interface requirements.

Machine-Made Cleanroom Ceiling Panels

Machine-Made Cleanroom Ceiling Panels

Machine-made cleanroom ceiling panels are suitable for projects requiring standardized panel dimensions and repetitive ceiling layouts.

Continuous manufacturing can provide consistent panel dimensions and efficient production for larger cleanroom areas. Depending on the selected panel construction, different core materials and metal facings can be combined to meet project requirements for thermal insulation, fire performance and surface finish. For ceiling applications, the panel construction should always be reviewed together with support spacing, suspension arrangement and required loads rather than simply using specifications intended for wall panels.

Cleanroom Ceiling Infill / Blank Panels

Cleanroom ceiling infill/ blank panels are used to close non-equipment areas within modular ceiling grids, particularly in layouts incorporating FFUs, HEPA filters, lights and other ceiling-mounted equipment.

The dimensions of the infill panels should match the selected ceiling grid and equipment modules. Joint sealing, panel retention, maintenance access and equipment support should also be coordinated during design.

Infill panels can also provide flexibility for future cleanroom modifications where ceiling equipment layouts may change.

Match the panel to the ceiling support system

Discuss the supporting structure, suspension points and service coordination with your design team before freezing the panel schedule.

Concealed-support panel ceilings

Review the panel edge profile, suspension connection, perimeter support and installation sequence. Define where access is required and how penetrations are reinforced and sealed.

Grid-supported ceiling layouts

Coordinate the panel module with the grid geometry and each light or filtration unit. T-grid, I-grid, Z-grid and FFU-grid descriptions refer to support approaches; they do not establish equivalent load capacity or universal compatibility.

Потолочные панели для чистых помещений

Need access above the room?

State the maintenance activity, access frequency and equipment weight. Ask for an engineered access solution and supporting documentation; do not treat every sandwich panel as a walking surface.

Compare Core Materials for your ceiling specification

The core material influences the weight, rigidity, thermal insulation, fire-related performance and installation requirements of a cleanroom ceiling panel.

There is no single core material suitable for every cleanroom ceiling. The appropriate construction should be selected according to the ceiling support system, span, service openings, maintenance requirements, operating environment and project specifications.

Glostar provides multiple cleanroom ceiling panel configurations for pharmaceutical, semiconductor, electronics, food processing, laboratory and other controlled environments.

Cleanroom ceiling panel core selection: project review guide
Core construction Selection focus Confirm for the ceiling
Rock wool Projects with defined fire and acoustic requirements Complete assembly test evidence, panel weight, support spacing and edge closure
PU / PIR Projects with thermal performance requirements Exact foam formulation, fire evidence, facing and joint compatibility
Magnesium oxide composite Composite build-ups requiring detailed material review Board specification, moisture conditions, facing protection and assembly weight
Aluminum honeycomb Projects considering a honeycomb construction Bonding system, reinforcement, surface finish and documented ceiling performance
Cleanroom_Double Layer Ceiling Grid System

Specify the assembly, not only the core

The same core can be used in different panel constructions. Faces, adhesives, edge profiles, reinforcement and support details all need to match the proposed use. Ask for documents tied to the exact configuration being quoted.

Cleanroom Ceiling Panel Specifications

Технические характеристикиAvailable Options / Project Requirements
Тип продуктаПотолочная панель для чистых помещений
Основной материалRock Wool / MGO Composite / Aluminum Honeycomb / PU / PIR
Толщина панелиCustomized according to ceiling system
Ширина панелиStandard or project-specific
Длина панелиCustomized according to ceiling layout
Facing MaterialОкрашенная сталь / Нержавеющая сталь / По индивидуальному заказу
Отделка поверхностиSmooth / Project-specific coating
ЦветБелый / Кремовый / По индивидуальному заказу
Ceiling OpeningsHEPA / FFU / Lighting / Sprinkler / Access Hatch
АрмированиеAccording to span, opening and load requirements
Support SystemGrid-supported / Concealed support / Project-specific
ЗаявкаPharmaceutical / Semiconductor / Electronics / Food / Laboratory
НастройкаDimensions / Openings / Facing / Core / Reinforcement

Cleanroom ceiling panel specifications should be confirmed according to the complete ceiling design rather than selected from a single standard dimension.

Panel thickness, module size, core material, metal facing, reinforcement and support spacing can affect the performance of the finished ceiling assembly. Projects incorporating HEPA filters, FFUs, lighting, sprinklers or access hatches also require coordinated openings and support details.

For customized projects, provide your reflected ceiling plan (RCP), cleanroom layout, BOQ or panel schedule. Glostar can review the available information and prepare a project-based cleanroom ceiling panel configuration for further technical evaluation and quotation.

Panel dimensions

Provide the module width, length, ceiling area and reflected ceiling plan. Coordinate dimensions with transport, handling and the service layout.

Thickness & build-up

State the preferred overall thickness, core, metal facing and any reinforcement. Final construction must be reviewed for ceiling use.

Facing & finish

Specify metal type, coating, color and appearance. Provide cleaning chemicals, concentrations and exposure conditions for compatibility review.

Supports & loading

Provide support spacing, suspension arrangement, equipment loads and access requirements. Require documented limits for the selected assembly.

Joints & sealing

Coordinate panel-to-panel joints, perimeter connections, sealant or gasket selection, and details around penetrations.

Fire & thermal requirements

Identify the applicable project requirements and requested evidence. Distinguish core classification from assembly fire resistance.

Openings & services

Schedule FFUs, HEPA housings, lights, sprinklers and hatches. Include each opening size, position, frame and load-support responsibility.

Quantity & delivery

Send the bill of quantities, project country, destination, requested delivery window and packaging or unloading constraints.

Have a ceiling drawing or bill of quantities?

Send your layout with the ceiling area, room use and maintenance-access requirement. Use the review to identify missing interfaces before comparing panel quotations.

Cleanroom Ceiling Panels by Application

Different industries require different cleanroom ceiling configurations. Air distribution, cleaning procedures, equipment density, humidity, maintenance access and regulatory requirements can all influence the selection of ceiling panels and support systems.

Glostar provides customized cleanroom ceiling panels for pharmaceutical, semiconductor, electronics, food, laboratory and other controlled-environment projects.

Pharmaceutical & Biotechnology Cleanroom Ceiling Panels

Pharmaceutical and biotechnology facilities require cleanroom ceilings that support contamination control, cleaning and coordinated installation with filtration and building services. Ceiling surfaces, joints and penetrations should be designed to create a cleanable enclosure while coordinating HEPA filters, lighting, sprinklers and access requirements. For pharmaceutical projects, the ceiling system should be evaluated together with cleanroom walls, HVAC, pressure control, doors and other enclosure components. The ceiling panel alone does not determine GMP compliance or cleanroom classification. Glostar can manufacture customized ceiling panels and coordinated openings according to project layouts and technical specifications.

Food Processing & Cosmetics Cleanroom Ceiling Panels

Food processing and cosmetics facilities may require ceiling surfaces that can withstand frequent cleaning, humidity and exposure to process conditions. Surface materials and coatings should be selected according to cleaning methods, chemicals, temperature and moisture conditions. Attention should also be given to ceiling penetrations, perimeter sealing and condensation risks, particularly in production areas with temperature or humidity differences. Customized cleanroom ceiling panels can be coordinated with lighting, ventilation and other services according to the hygienic requirements of the facility.

Laboratory & Medical Cleanroom Ceiling Panels

Laboratories and medical controlled environments can have very different ceiling requirements depending on room function, cleanliness requirements, equipment and maintenance procedures.

Cleanroom ceiling panels provide smooth overhead enclosure surfaces and can be integrated with filtration, lighting, sprinklers and service openings.

For environments exposed to frequent disinfection or specific chemicals, facing materials and coatings should be selected according to the actual cleaning procedure.

The complete ceiling design should also consider service density, access requirements and interfaces with cleanroom walls, doors and windows.

Modular Cleanroom Ceiling Systems

Modular cleanrooms benefit from coordinated wall and ceiling components that can be prefabricated according to a defined room layout.

Cleanroom ceiling panels can be manufactured to match modular wall systems, doors, windows and equipment interfaces, helping reduce unnecessary site modification.

For projects requiring future expansion or layout changes, modular ceiling systems can also provide greater flexibility when service modules and panel dimensions are planned appropriately.

Early coordination of ceiling grids, filtration, lighting and access requirements can simplify installation and future maintenance.

Resolve these installation interfaces before production

The installation method must follow the approved project drawings and the selected system instructions. Use the following sequence as a coordination checklist.

01 · Confirm the layout

Freeze room dimensions, panel joints and the reflected ceiling plan. Identify obstructions and available suspension points above the room.

02 · Coordinate services

Agree filter, light and access-hatch positions with the MEP team. Define support responsibilities and maintenance clearances for each component.

03 · Approve construction details

Review suspension, perimeter, joints and penetrations. Confirm the ceiling access policy and applicable design documentation.

04 · Organize delivery

Confirm panel identification, packing sequence and site storage. Protect faces, edges and core materials during handling.

05 · Install & inspect

Check alignment, fastening and sealing against approved details. Record deviations and obtain design review before changing openings or supports.

06 · Complete handover

Document the installed arrangement and access restrictions. Coordinate enclosure checks with the cleanroom commissioning and testing plan.

Cleanroom Ceiling Panel Manufacturing & Quality Control

Cleanroom ceiling panel quality affects panel dimensions, surface appearance, joint consistency, installation accuracy and the overall performance of the cleanroom enclosure.

For project-based production, Glostar manufactures cleanroom ceiling panels according to confirmed specifications, drawings and project requirements. Panel construction, dimensions, facing materials, core materials, edge details, reinforcement and prefabricated openings should be reviewed before production.

Panel Construction Review

Before production, confirm the complete panel configuration rather than only the core material or thickness.

The review should include panel dimensions, core material, metal facing, surface finish, edge profile, reinforcement, joint details and required openings.

For customized ceiling projects, HEPA filters, FFUs, lights, access hatches and other service openings should be coordinated with the reflected ceiling plan before fabrication.

Dimensional & Appearance Inspection

Inspection requirements can be agreed according to the project and supplied panel configuration.

Typical inspection items may include panel dimensions, thickness, surface condition, flatness, edge quality, opening dimensions, protective film, panel identification and packaging.

For international cleanroom projects, consistent panel identification can also help contractors organize materials according to the installation sequence.

Проект по созданию чистых помещений на биофармацевтическом предприятии «Шандун Айшицзинь»

Project Documentation

Technical documents should correspond to the actual product configuration being supplied.

Depending on the project requirements, buyers may request product specifications, drawings, joint details, material information and applicable test reports.

Where fire, structural or other performance documentation is required, confirm that the test configuration and scope are relevant to the proposed ceiling assembly.

Packaging for International Projects

Cleanroom ceiling panels should be protected during loading, transportation and site storage to reduce damage to surfaces, edges and joint profiles.

Packaging requirements can be coordinated according to panel dimensions, shipment method and project installation sequence.

For large international projects, panel marks and packing lists can also help contractors identify materials and organize installation on site.

Cleanroom Ceiling Panel Solutions for B2B Projects

Cleanroom ceiling panel requirements vary according to the buyer’s role in the project. Contractors may focus on installation and ceiling coordination, EPC companies need to integrate multiple engineering systems, while procurement teams often evaluate specifications, documentation, pricing and delivery.

Glostar supports project-based cleanroom ceiling panel supply for contractors, EPC companies, distributors, procurement teams and industrial project owners.

For cleanroom contractors

For cleanroom contractors, accurate panel dimensions, coordinated openings and clear installation details are important for keeping installation on schedule.

Glostar can manufacture cleanroom ceiling panels according to approved ceiling layouts, panel schedules and technical specifications. Openings for HEPA filters, FFUs, lighting, access hatches and other services can be coordinated before production according to project requirements.

Panel identification, drawings and packing information can also support material organization and installation on international projects.

Suitable for: Cleanroom contractors, installation companies and specialist cleanroom subcontractors.

For Cleanroom EPC Companies

Cleanroom ceiling systems often need close coordination between architectural design, HVAC, MEP services, filtration equipment, lighting and fire protection.

Glostar can support EPC companies by reviewing cleanroom ceiling layouts and panel requirements before production. Panel modules, service openings, interfaces and enclosure components can be coordinated according to the available project information.

For projects requiring complete cleanroom enclosure supply, ceiling panels can also be coordinated with cleanroom wall panels, doors, windows and related accessories.

Suitable for: Pharmaceutical EPC projects, electronics factories, semiconductor facilities, food plants and advanced manufacturing projects.

Cleanroom panel distributors

Distributors often need flexible cleanroom ceiling panel configurations for different industries and local project requirements.

Glostar provides multiple core materials, facing options, panel constructions and customized dimensions. Technical information and project quotation support can be provided according to the inquiry.

For project-based orders, distributors can send customer drawings, BOQs or specifications for further evaluation.

Suitable for: Cleanroom product distributors, building material importers and regional suppliers.

For Cleanroom Project Owners

Project owners need to balance cleanroom performance, installation schedule, maintenance requirements and project investment.

Glostar can help review cleanroom ceiling panel configurations according to the facility application, cleaning environment, ceiling layout, filtration arrangement and technical requirements.

For new facilities and cleanroom renovation projects, wall panels, ceiling panels, doors and windows can also be coordinated as part of the overall cleanroom enclosure.

Suitable for: Pharmaceutical manufacturers, semiconductor companies, food producers, laboratories, medical facilities and industrial facility owners.

What Affects Cleanroom Ceiling Panel Prices?

There is no universal cleanroom ceiling panel price per square meter because the final cost depends on the panel construction, ceiling system, service openings, order quantity and project delivery requirements.

For B2B projects, quotations should be compared according to the same technical specification and supply scope.

Core Material & Panel Construction

Rock wool, MGO composite, aluminum honeycomb and PU/PIR panels have different material structures and manufacturing requirements.

Panel thickness, facing material, coating, reinforcement and edge construction also influence the final cost.

Ceiling Support System

The total ceiling package may include more than panels.

Grid profiles, concealed supports, suspension components, perimeter trims and connection accessories can affect the overall project cost.

Always confirm which components are included in the quotation.

Quantity & Customization

Larger standardized orders may have different production economics from small projects requiring multiple customized panel dimensions and openings.

The quantity, panel schedule and degree of customization should therefore be confirmed when requesting a quotation.

Packaging & Shipping

For international projects, panel dimensions, packaging method, container utilization, destination and shipping terms can affect the delivered project cost.

Special packing or panel identification requirements should also be discussed before quotation.

Clean Room Wall Panel FAQs

Основное отличие заключается в том, что потолочные панели для чистых помещений предназначены для контролируемых сред, где важную роль играют такие факторы, как возможность очистки, герметичность, интеграция инженерных систем и контроль загрязнения. Обычные подвесные потолки в основном используются для создания внутренней отделки потолка и скрытия инженерных коммуникаций здания. Потолки для чистых помещений должны дополнительно учитывать стыки, периметральные соединения, фильтрующее оборудование, освещение, проходы и другие сопряжения. Поэтому отделка поверхности, конструкция стыков, опоры потолка, отверстия для инженерных коммуникаций и требования к очистке должны оцениваться как часть комплексной системы потолка для чистых помещений.

Потолочная панель для чистой комнаты представляет собой один из компонентов, тогда как система потолка для чистой комнаты включает в себя панели вместе с несущей конструкцией, подвесными элементами, профилями, соединительными элементами, уплотнительными деталями и встроенными инженерными сетями.

В зависимости от проекта в состав полной системы могут входить:

Потолочные панели для чистых помещений

Потолочная решетка или скрытая несущая конструкция

Компоненты подвески

Профили по периметру

Фильтры HEPA или FFU

Освещение

Спринклеры

Люки доступа

Уплотнительные принадлежности

При сравнении предложений покупателям следует уточнить, включает ли предложение поставщика только панели или же более полный комплект потолочной системы.

Не существует единого материала для каркаса, который подходил бы для любого проекта потолка в чистом помещении.

Минеральная вата обычно используется в тех случаях, когда важным требованием является огнестойкость. Композитные конструкции на основе МГО можно рассматривать в тех случаях, когда требуется дополнительная жесткость и использование композитных материалов. Алюминиевый сотовый материал обеспечивает легкую конструкцию с хорошей жесткостью и плоскостностью панелей, а полиуретан (PU)/полиизоцианурат (PIR) — высокие теплоизоляционные характеристики по отношению к своей толщине.

Выбор подходящего материала для сердцевины должен осуществляться с учетом требований пожарной безопасности, пролета перекрытия, веса панели, теплотехнических характеристик, схемы опор, проёмов для инженерных коммуникаций, требований к техническому обслуживанию и проектных условий.

При технической оценке следует учитывать конструкцию панели в целом, а не только материал сердцевины.

Толщина потолочных панелей для чистых помещений должна выбираться с учетом общей конструкции потолка, а не на основе единого стандартного значения для всех проектов. Требуемая толщина может зависеть от следующих факторов: Материал сердцевины Размеры панелей Расстояние между опорами Пролет потолка Армирование Технические проемы Теплотехнических требований Требований к техническому обслуживанию Указанных нагрузок Более толстая панель не всегда означает, что по потолку можно ходить или что он выдерживает более высокие нагрузки. Если вы не уверены, какая толщина подходит, предоставьте план отраженного потолка, размеры панелей, схему расположения опор и требуемые эксплуатационные характеристики, чтобы можно было оценить конфигурацию потолка в целом.

Не все потолочные панели для чистых помещений пригодны для хождения по ним.

Возможность доступа персонала к потолку чистой комнаты зависит от конструкции потолочной системы в целом, включая конструкцию панелей, облицовочные материалы, арматуру, пролет панелей, расстояние между опорами, подвесную систему, соединения, а также требуемые сосредоточенные или распределенные нагрузки.

Не следует руководствоваться только толщиной панели при определении того, безопасен ли потолок для доступа персонала.

Если персоналу по техническому обслуживанию требуется доступ к пространству над чистой комнатой для обслуживания фильтров HEPA, блоков FFU, осветительного оборудования или другого оборудования, необходимые грузоподъемные возможности и способ доступа должны быть определены на этапе проектирования.

Прежде чем разрешить персоналу доступ к потолку, необходимо проверить, выдерживает ли вся конструкция потолка указанные нагрузки.

Потолок чистой комнаты, по которому можно ходить, представляет собой инженерную потолочную конструкцию, рассчитанную на выдерживание заданных нагрузок от персонала или технического обслуживания при одновременном обеспечении необходимой герметичности чистой комнаты. Потолок, по которому можно ходить, — это не просто более толстая многослойная панель для чистой комнаты. Его эксплуатационные характеристики зависят от взаимодействия потолочных панелей, арматуры, несущих профилей, точек подвеса, соединений и конструкции. Потолки чистых помещений, по которым можно ходить, часто рассматриваются в тех случаях, когда техническому персоналу требуется регулярный доступ к оборудованию, расположенному над чистым помещением, например к фильтрам, воздуховодам, осветительным приборам или инженерным сетям. Перед выбором потолочной системы необходимо четко определить требуемые условия нагрузки и способ доступа.
Потолочные панели для чистых помещений могут крепиться с помощью различных решеточных, профильных или скрытых опорных систем в зависимости от конструкции потолка. При проектировании системы крепления необходимо учитывать размеры панелей, пролет потолка, вес панелей, отверстия для оборудования, точки подвеса и требуемые нагрузки. В некоторых проектах панели устанавливаются в модульную потолочную решетку. В других проектах могут использоваться скрытые опоры или подвесные системы, разработанные специально для данного проекта. Потолочные панели и система опор всегда следует оценивать комплексно, поскольку изменение расстояния между опорами может повлиять на эксплуатационные характеристики панелей и всей потолочной конструкции в целом.

Да. Потолочные панели для чистых помещений могут быть выполнены с отверстиями для фильтров HEPA, вентиляторно-фильтрующих блоков (FFU), освещения и других потолочных систем.

Расположение и размеры этих проемов желательно указать на чертеже отраженного плана потолка до начала изготовления панелей.

Для каждого проёма проектная группа должна учитывать вопросы каркаса, армирования, герметизации, опоры оборудования и пространства для технического обслуживания.

По возможности, предварительная изготовка согласованных проемов позволяет сократить объем ненужной резки и доработок в ходе монтажа.

В чистых помещениях для производства полупроводников и электроники с высокой плотностью размещения блоков FFU потолочная решетка, модули оборудования и заполняющие панели должны быть согласованы как единая интегрированная система.

Да. Потолочные панели для чистых помещений широко используются в качестве элемента систем ограждения в контролируемых средах фармацевтической и биотехнологической отраслей.

При применении в фармацевтической отрасли поверхности потолков и стыки следует выбирать с учетом требований к простоте очистки, герметичности, процедур очистки, а также интеграции с системами фильтрации HEPA, освещением, спринклерными системами и другими инженерными сетями.

Однако одна только потолочная панель не делает объект соответствующим требованиям GMP.

Соблюдение требований GMP зависит от комплексного проектирования объекта, используемых материалов, системы отопления, вентиляции и кондиционирования воздуха (ОВКВ), системы контроля давления, качества строительства, аттестации персонала, процедур очистки и эксплуатации.

Поэтому технические характеристики потолочных панелей следует выбирать в соответствии с применимыми к проекту требованиями и общим проектом чистой комнаты.

Потолочные панели для чистых помещений могут использоваться в составе объектов, рассчитанных на различные классы чистоты по стандарту ISO, включая среды классов ISO 5, ISO 7 и ISO 8. Однако классификация чистоты по стандарту ISO относится к контролируемой среде в целом, а не к отдельной потолочной панели. Окончательный уровень чистоты зависит от таких факторов, как фильтрация воздуха, воздушный поток, схема воздухообмена, давление в помещении, герметичность, стыки потолка и стен, двери, проемы, рабочие процедуры и меры по контролю загрязнения. Роль потолочной системы заключается в обеспечении надлежащего верхнего ограждения, которое может быть интегрировано в общую конструкцию чистой комнаты.

Стандарт ISO 14644 в первую очередь касается чистых помещений и связанных с ними контролируемых сред, а не предусматривает универсальную сертификацию отдельных потолочных панелей для чистых помещений.

По этой причине покупателям следует с осторожностью относиться к таким заявлениям, как “потолочная панель, сертифицированная по стандарту ISO класса 5”, не имея представления о том, что именно было проверено или сертифицировано.

Классификация чистых помещений определяется на уровне отдельного помещения или объекта в соответствии с применимыми процедурами и условиями эксплуатации.

При закупке потолочных панелей следует внимательно изучить технические характеристики продукции, материалы, свойства поверхности, конструкцию стыков, проектные требования и соответствующую сопроводительную документацию, а не полагаться исключительно на отдельное заявление о том, что “панели сертифицированы по стандарту ISO”.

Yes. Cleanroom ceiling panels can be used for new construction, renovation, extension and partial ceiling replacement projects.

Renovation projects usually require additional site verification because new panels may need to interface with existing ceiling grids, supports, walls, HVAC equipment and building services.

Before manufacturing replacement panels, verify the existing module dimensions, panel edges, support arrangement, service openings and connection details.

Where possible, provide existing drawings together with current site measurements and photographs.

This information helps determine whether standard panels can be used or customized replacement panels are required.

Получите мгновенный расчет стоимости

Контактная форма

Request Your Cleanroom Ceiling Panel Quote

Tell us about your ceiling area, application and project location. Include “cleanroom ceiling panels” in your message so the inquiry can be directed to the right product discussion.

Have drawings to share?

Email your layout and panel schedule with the project name. Include any specified loading, finish and documentation requirements.

Tell us about your project

Форма в нижнем колонтитуле главной страницы

Получите мгновенный расчет стоимости​

Контактная форма

Запланировать встречу​

Посетите стенд компании Glostar на 140-й Кантонской ярмарке, которая пройдет 23–27 октября 2026 года, стенд 13.1K26.
Скачать форму
Логотип Glostar

ПРИГЛАШАЕМ ВАС

КАНТОНСКАЯ ЯРМАРКА

2026

ВСТРЕТИМСЯ НА

Стенд 13.1K26

КОМПЛЕКСНЫЕ РЕШЕНИЯ В ОБЛАСТИ СТРОИТЕЛЬНЫХ МАТЕРИАЛОВ

ПОЗНАКОМЬТЕСЬ С GLOSTAR

Посетите стенд компании Glostar на 140-й Кантонской ярмарке

Ознакомьтесь с комплексными решениями Glostar для чистых помещений, включая стеновые и потолочные панели, двери, окна и модульные системы для чистых помещений.

Познакомьтесь с нашей командой в Гуанчжоу, чтобы обсудить ваши будущие проекты в сфере фармацевтики, электроники и промышленных чистых помещений.

КОГДА

23–27 октября 2026 года

ГДЕ

Гуанчжоу, Китай

СТЕНД
13.1K26
Давайте обсудим ваш следующий строительный проект.
Этот контент заблокирован, поскольку он пытается установить соединение с YouTube.

Получите мгновенный расчет стоимости​

Контактная форма