Product Overview
The Corrosion & VHP Resistant Aluminum Honeycomb Cleanroom Panel is a high-performance cleanroom enclosure panel developed for facilities where conventional cleanroom panels may be exposed to frequent disinfection, chemical cleaning, or aggressive environmental conditions.
Its aluminum honeycomb core provides an excellent strength-to-weight ratio, allowing the panel to remain lightweight while maintaining high rigidity and dimensional stability. Combined with suitable corrosion-resistant facings and sealed panel joints, the system is particularly suitable for pharmaceutical and biotechnology facilities using stringent cleaning and decontamination procedures.
The panels can be manufactured for both cleanroom wall and ceiling applications and integrated with cleanroom doors, windows, coving profiles, equipment openings, and other enclosure components according to project drawings.
Engineered for VHP Decontamination Environments
VHP, or Vaporized Hydrogen Peroxide, is widely used as a decontamination method in controlled environments where microbial contamination must be strictly managed.
Because cleanroom wall and ceiling surfaces may be repeatedly exposed to decontamination cycles throughout the facility’s service life, the materials used in the enclosure system need to be selected with long-term surface durability in mind.
Glostar’s VHP-resistant cleanroom panel can be configured with corrosion-resistant surface materials and compatible sealing solutions to meet the requirements of demanding pharmaceutical and biotechnology environments.
This makes the panel particularly suitable for areas where:
- VHP decontamination is regularly performed
- Frequent cleaning and disinfection are required
- Conventional coated surfaces may face accelerated deterioration
- Long-term surface integrity is important
- Cleanability and contamination control are critical
Technical Specifications
| Item | Specifiche tecniche |
| Product Name | Pannello per camere bianche in alluminio a nido d'ape resistente alla corrosione e al VHP |
| Materiale del nucleo | Aluminum Honeycomb |
| Materiale della superficie | Corrosion-resistant Cleanroom-grade Metal Sheet |
| Spessore del pannello | 50 / 75 / 100 mm or Customized |
| Panel Width | Standard or Customized |
| Panel Length | Customized According to Project |
| Surface Finish | Smooth / Corrosion-resistant Finish |
| Panel Type | Wall Panel / Ceiling Panel |
| Edge Structure | Reinforced / Project-specific |
| Joint Type | Modular Cleanroom Joint |
| VHP Compatibility | Available According to Surface Configuration |
| Chemical Resistance | Project-specific Surface Options |
| Color | Standard White / Customized |
| Openings | Factory-prepared According to Drawings |
| Applicazione | Pharmaceutical, Biotech, Laboratory & Controlled Environments |
| Personalizzazione | Available |
Why Choose This Panel for Pharmaceutical & Biotech Projects?
Cleanroom enclosure materials in pharmaceutical and biotech facilities need to perform throughout repeated cleaning and decontamination cycles.
The Corrosion & VHP Resistant Aluminum Honeycomb Cleanroom Panel addresses this requirement through a combination of surface durability and structural performance.
VHP-Compatible Surface Options
Surface materials can be selected for environments where VHP decontamination is part of the facility’s cleaning protocol.
Enhanced Corrosion Resistance
Suitable surface configurations help protect the panel against moisture, disinfectants, and demanding cleaning conditions.
Lightweight but Rigid
The aluminum honeycomb structure provides excellent stiffness without unnecessary panel weight.
Smooth Hygienic Surface
Flat surfaces and controlled joints simplify routine cleaning and help reduce areas where contaminants can accumulate.
Wall and Ceiling Flexibility
The panel can be configured for different parts of the cleanroom enclosure system.
Project-Specific Manufacturing
Dimensions, surface materials, openings, connection details, and panel configurations can be manufactured according to approved project drawings.
Quality Assurance
GloStar’s cleanroom panes are produced under ISO 9001 quality management, with incoming glass inspection, dimensional checks on every batch, and fire performance backed by third-party test reports. CE-compliant documentation and fire test certificates can be provided for export and project approval.
Domande frequenti
What is a VHP resistant cleanroom panel?
A VHP resistant cleanroom panel is an enclosure panel designed with surface materials and sealing systems suitable for environments where Vaporized Hydrogen Peroxide may be used for decontamination. Material selection is important because repeated VHP exposure and cleaning procedures can affect conventional surfaces over time.
Can the panel dimensions be customized?
Yes. Panel thickness, width, length, surface material, finish, joint details, openings, and other specifications can be customized according to cleanroom drawings and technical requirements.
Is the panel resistant to all disinfectants and chemicals?
Chemical resistance depends on the specific surface material, coating, chemical type, concentration, temperature, contact time, and frequency of exposure. Customers should provide their cleaning and decontamination requirements so that the appropriate surface configuration can be selected.
Can doors, windows and equipment openings be integrated into the panel system?
Yes. Panels can be manufactured according to project drawings and coordinated with cleanroom doors, flush windows, pass boxes, equipment openings, utility penetrations, and other cleanroom system components.
Request a Quotation
Send Glostar your cleanroom drawings, panel dimensions, quantity, wall or ceiling application, surface requirements, VHP/decontamination conditions, and project location.